{"product_id":"environ-warmepumpe-mit-550-liter-hygienespeicher-fur-brauchwasser-und-heizung","title":"A+++ Mitsui heat pump with 550 liters of hygienic storage for domestic water and heating","description":"\u003cp\u003e \u003cspan data-mce-fragment=\"1\"\u003eEnviron - Mitsui monoblock units are characterized by integrated cooling and hydronic modules that make it possible to extract heat from the outside air and thus heat the interior and vice versa.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan data-mce-fragment=\"1\"\u003eThey are therefore a bivalent, ecological and renewable solution. They can be positioned directly on the external wall, on the ground or on the roof.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWhy choose an\u003c\/span\u003e \u003cspan data-mce-fragment=\"1\"\u003eEnviron - Mitsui\u003c\/span\u003e \u003cspan data-mce-fragment=\"1\"\u003eheat pump\u003c\/span\u003e \u003cspan data-mce-fragment=\"1\"\u003e?\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e✓ Mitsui systems are able to guarantee high levels of efficiency and adapt to any climatic condition thanks to an appropriate design of the structural components and the thermodynamic cycle. They guarantee synergy between the equipment in the system and adapt to the energy needs to achieve optimal comfort in both winter and summer.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan data-mce-fragment=\"1\"\u003eThe Mitsui heat pump range offers a wide selection of products ranging from 4 kW (single phase) to 16 kW (three phase), suitable for any type of building, whether it is a renovation or a new build\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e✓ Mitsui offers two product lines of heat pumps, one for heating and one for domestic hot water: the monoblock line and the split line. Both lines are in class A++ (see European legislation on energy efficiency) and contribute significantly to reducing environmental impact, achieving significant energy savings and reducing operating costs.\u003c\/span\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eIn order to fully complete its range of heat pumps, Mitsui has decided to expand its offer to include air-water heat pumps for the production of domestic hot water only. The line of monoblock water heaters is equipped with three different tanks for storing domestic hot water: 100 litres, 180 litres and 280 litres. For the last two sizes, the tanks can be completed with a coil for solar thermal energy or another additional heat source of 1.1 m2 for the second size and 1.3 m2 for the third. This product line guarantees Class A+ according to the ErP directive and helps to limit running costs and environmental impact.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-mce-fragment=\"1\"\u003eTechnical data 5 kW heat pump\u003cbr data-mce-fragment=\"1\"\u003e ▸ Power supply: V\/Ph\/Hz: 220-240\/1\/50\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating² :\u003cbr data-mce-fragment=\"1\"\u003e ▸ Capacity: 4.65 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Nominal input power: 0.93 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ COP: 5.00\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating³:\u003cbr data-mce-fragment=\"1\"\u003e ▸ Capacity: 4.65 kW\u003c\/span\u003e \u003cbr data-mce-fragment=\"1\"\u003e▸ Nominal input power: 1.77 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ COP: 2.63\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling⁴\u003cbr data-mce-fragment=\"1\"\u003e ▸ Capacity: 4.60 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Nominal input power: 0.95 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ EER: 4.82\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling⁵\u003cbr data-mce-fragment=\"1\"\u003e ▸ Capacity: 4.85 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Nominal input power: 1.63 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ EER: 2.98\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Seasonal room heating Energy efficiency class⁶: LWT at 35 °C: A+++\u003cbr data-mce-fragment=\"1\"\u003e ▸ SCOP6: LWT at 35 °C: 4.47\u003cbr data-mce-fragment=\"1\"\u003e ▸ SEER6:\u003cbr data-mce-fragment=\"1\"\u003e ▸ LWT at 7 °C: 4.71\u003cbr data-mce-fragment=\"1\"\u003e ▸ LWT at 18 °C: 7.61\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Sound level⁷: 61 dB(A)\u003cbr data-mce-fragment=\"1\"\u003e ▸ Outdoor fan: air flow 3050 m3\/h\u003cbr data-mce-fragment=\"1\"\u003e ▸ Net dimensions (WxHxD): 1210×945×402 mm\u003cbr data-mce-fragment=\"1\"\u003e ▸ Dimensions with packaging (WxHxD): 1500×1140×450 mm\u003cbr data-mce-fragment=\"1\"\u003e ▸ Net\/gross weight: 92\/111 kg\u003cbr data-mce-fragment=\"1\"\u003e ▸ Water pipe connections: 1” AG BSP\u003cbr data-mce-fragment=\"1\"\u003e ▸ Safety valve response pressure: 0.3 MPa\u003cbr data-mce-fragment=\"1\"\u003e ▸ Total water volume: 2.0 L\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Operating temperature range:\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling: -5 to 43°C\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating: -25 to 35°C\u003cbr data-mce-fragment=\"1\"\u003e ▸ DHW: -25 to 43°C\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ LWT area:\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling: 5 to 25\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating: 25 to 60\u003cbr data-mce-fragment=\"1\"\u003e ▸ DHW: 40 to 60\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Refrigerant\u003cbr data-mce-fragment=\"1\"\u003e ▸ Type: R32\u003cbr data-mce-fragment=\"1\"\u003e ▸ Loaded volume: 2.0 kg\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Throttle valve type: Electronic expansion valve \u003cbr data-mce-fragment=\"1\"\u003e▸ Additional electric heating: Optional ✓: 3.0 kW\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e 1. Relevant EU standards and legislation: EN14511: 2016; EN14825: 2016;\u003cbr data-mce-fragment=\"1\"\u003e EN50564: 2011; EN12102:2017; (EU) N° 811\/2013; (EU) N° 813\/2013;\u003cbr data-mce-fragment=\"1\"\u003e OJ 2014\/C 207\/02; OJ 2017\/C 229\/01.\u003cbr data-mce-fragment=\"1\"\u003e 2. Outdoor temperature 7°C DB, 85% RH; EWT 30°C, LWT 35°C.\u003cbr data-mce-fragment=\"1\"\u003e 3. Outdoor temperature 7°C DB, 85% RH; EWT 47°C, LWT 55°C.\u003cbr data-mce-fragment=\"1\"\u003e 4. Outside temperature 35°C DB; EWT 23°C, LWT 18°C.\u003cbr data-mce-fragment=\"1\"\u003e 5. Outside temperature 35°C DB; EWT 12°C, LWT 7°C.\u003cbr data-mce-fragment=\"1\"\u003e 6. Energy efficiency class of seasonal space heating, tested under\u003cbr data-mce-fragment=\"1\"\u003e average climatic conditions\u003cbr data-mce-fragment=\"1\"\u003e 7. Sound power level tested under average climatic conditions:\u003cbr data-mce-fragment=\"1\"\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 30°C, LWT 35°C;\u003cbr data-mce-fragment=\"1\"\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 47°C, LWT 55°C;\u003cbr data-mce-fragment=\"1\"\u003e - cooling: outside temperature 35°C DB, 24°C WB; EWT 12°C, LWT 7°C.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e Technical data heat pump 7 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Power supply: V\/Ph\/Hz: 220-240\/1\/50\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating² :\u003cbr data-mce-fragment=\"1\"\u003e ▸ Capacity: 6.65 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Nominal input power: 1.35 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ COP: 4.94\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating³: \u003cbr data-mce-fragment=\"1\"\u003e▸ Capacity: 6.80 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Nominal input power: 2.42 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ COP: 2.81\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling⁴\u003cbr data-mce-fragment=\"1\"\u003e ▸ Capacity: 6.45 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Nominal input power: 1.39 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ EER: 4.65\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling⁵\u003cbr data-mce-fragment=\"1\"\u003e ▸ Capacity: 6.30 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ Nominal input power: 2.27 kW\u003cbr data-mce-fragment=\"1\"\u003e ▸ EER: 2.77\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Seasonal room heating Energy efficiency class⁶: LWT at 35 °C: A+++\u003cbr data-mce-fragment=\"1\"\u003e ▸ SCOP6: LWT at 35 °C: 4.47\u003cbr data-mce-fragment=\"1\"\u003e ▸ SEER6:\u003cbr data-mce-fragment=\"1\"\u003e ▸ LWT at 7 °C: 4.99\u003cbr data-mce-fragment=\"1\"\u003e ▸ LWT at 18 °C: 8.58\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Sound level⁷: 64 dB(A)\u003cbr data-mce-fragment=\"1\"\u003e ▸ Outdoor fan: air flow 3050 m3\/h\u003cbr data-mce-fragment=\"1\"\u003e ▸ Net dimensions (WxHxD): 1210×945×402 mm\u003cbr data-mce-fragment=\"1\"\u003e ▸ Dimensions with packaging (WxHxD): 1500×1140×450 mm\u003cbr data-mce-fragment=\"1\"\u003e ▸ Net\/gross weight: 92\/111 kg\u003cbr data-mce-fragment=\"1\"\u003e ▸ Water pipe connections: 1” AG BSP\u003cbr data-mce-fragment=\"1\"\u003e ▸ Safety valve response pressure: 0.3 MPa\u003cbr data-mce-fragment=\"1\"\u003e ▸ Total water volume: 2.0 L\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Operating temperature range:\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling: -5 to 43°C\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating: -25 to 35°C\u003cbr data-mce-fragment=\"1\"\u003e ▸ DHW: -25 to 43°C\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ LWT area:\u003cbr data-mce-fragment=\"1\"\u003e ▸ Cooling: 5 to 25\u003cbr data-mce-fragment=\"1\"\u003e ▸ Heating: 25 to 60\u003cbr data-mce-fragment=\"1\"\u003e ▸ DHW: 40 to 60\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Refrigerant\u003cbr data-mce-fragment=\"1\"\u003e ▸ Type: R32\u003cbr data-mce-fragment=\"1\"\u003e ▸ Loaded volume: 2.0 kg\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e ▸ Throttle valve type: Electronic expansion valve \u003cbr data-mce-fragment=\"1\"\u003e▸ Additional electric heating: Optional ✓: 3.0 kW\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e 1. Relevant EU standards and legislation: EN14511: 2016; EN14825: 2016;\u003cbr data-mce-fragment=\"1\"\u003e EN50564: 2011; EN12102:2017; (EU) N° 811\/2013; (EU) N° 813\/2013;\u003cbr data-mce-fragment=\"1\"\u003e OJ 2014\/C 207\/02; OJ 2017\/C 229\/01.\u003cbr data-mce-fragment=\"1\"\u003e 2. Outdoor temperature 7°C DB, 85% RH; EWT 30°C, LWT 35°C.\u003cbr data-mce-fragment=\"1\"\u003e 3. Outdoor temperature 7°C DB, 85% RH; EWT 47°C, LWT 55°C.\u003cbr data-mce-fragment=\"1\"\u003e 4. Outside temperature 35°C DB; EWT 23°C, LWT 18°C.\u003cbr data-mce-fragment=\"1\"\u003e 5. Outside temperature 35°C DB; EWT 12°C, LWT 7°C.\u003cbr data-mce-fragment=\"1\"\u003e 6. Energy efficiency class of seasonal space heating, tested under\u003cbr data-mce-fragment=\"1\"\u003e average climatic conditions\u003cbr data-mce-fragment=\"1\"\u003e 7. Sound power level tested under average climatic conditions:\u003cbr data-mce-fragment=\"1\"\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 30°C, LWT 35°C;\u003cbr data-mce-fragment=\"1\"\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 47°C, LWT 55°C;\u003cbr data-mce-fragment=\"1\"\u003e - cooling: outside temperature 35°C DB, 24°C WB; EWT 12°C, LWT 7°C.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan\u003eTechnical data heat pump 9 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Power supply: V\/Ph\/Hz: 220-240\/1\/50\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Heating² :\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Capacity: 8.60 kW\u003c\/span\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cspan\u003e▸ Nominal input power: 1.87 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ COP: 4.60\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Heating³:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Capacity: 8.60 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Nominal input power: 3.13 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ COP: 2.75\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Cooling⁴\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Capacity: 8.00 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Nominal input power: 1.92 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ EER: 4.16\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Cooling⁵\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Capacity: 7.95 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Nominal input power: 3.15 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ EER: 2.53\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Seasonal room heating Energy efficiency class⁶: LWT at 35 °C: A+++\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ SCOP6: LWT at 35 °C: 4.51\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ SEER6:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ LWT at 7 °C: 4.92\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ LWT at 18 °C: 7.88\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Sound level⁷: 67 dB(A)\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Outdoor fan: air flow 3050 m3\/h\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Net dimensions (WxHxD): 1210×945×402 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Dimensions with packaging (WxHxD): 1500×1140×450 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Net\/gross weight: 92\/111 kg\u003c\/span\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cspan\u003e▸ Water pipe connections: 1” AG BSP\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Safety valve response pressure: 0.3 MPa\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Total water volume: 2.0 L\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Operating temperature range:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Cooling: -5 to 43°C\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Heating: -25 to 35°C\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ DHW: -25 to 43°C\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ LWT area:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Cooling: 5 to 25\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Heating: 25 to 60\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ DHW: 40 to 60\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Refrigerant\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Type: R32\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Loaded volume: 2.0 kg\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Throttle valve type: Electronic expansion valve\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e▸ Additional electric heating: Optional ✓: 3.0 kW\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e1. Relevant EU standards and legislation: EN14511: 2016; EN14825: 2016;\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003eEN50564: 2011; EN12102:2017; (EU) N° 811\/2013; (EU) N° 813\/2013;\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003eOJ 2014\/C 207\/02; OJ 2017\/C 229\/01.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e2. Outdoor temperature 7°C DB, 85% RH; EWT 30°C, LWT 35°C.\u003c\/span\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003cspan\u003e3. Outdoor temperature 7°C DB, 85% RH; EWT 47°C, LWT 55°C.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e4. Outside temperature 35°C DB; EWT 23°C, LWT 18°C.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e5. Outside temperature 35°C DB; EWT 12°C, LWT 7°C.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e6. Energy efficiency class of seasonal space heating, tested under\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003eaverage climatic conditions\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e7. Sound power level tested under average climatic conditions:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e- heating: outside temperature 7°C DB, 6°C WB; EWT 30°C, LWT 35°C;\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e- heating: outside temperature 7°C DB, 6°C WB; EWT 47°C, LWT 55°C;\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cspan\u003e- cooling: outside temperature 35°C DB, 24°C WB; EWT 12°C, LWT 7°C.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan\u003eTechnical data heat pump 12 kW\u003cbr\u003e ▸ Power supply: V\/Ph\/Hz: 220-240\/1\/50\u003cbr\u003e\u003cbr\u003e ▸ Heating² :\u003cbr\u003e ▸ Capacity: 12.30 kW\u003cbr\u003e ▸ Nominal input power: 2.56 kW\u003cbr\u003e ▸ COP: 4.81\u003cbr\u003e\u003cbr\u003e ▸ Heating³:\u003cbr\u003e ▸ Capacity: 11.90 kW\u003cbr\u003e ▸ Nominal input power: 4.28 kW\u003cbr\u003e ▸ COP: 2.78\u003cbr\u003e\u003cbr\u003e ▸ Cooling⁴\u003cbr\u003e ▸ Capacity: 12.20 kW\u003cbr\u003e ▸ Nominal input power: 2.55 kW\u003cbr\u003e ▸ EER: 4.78\u003cbr\u003e\u003cbr\u003e ▸ Cooling⁵\u003c\/span\u003e \u003cbr\u003e▸ Capacity: 10.90 kW\u003cbr\u003e ▸ Nominal input power: 3.74 kW\u003cbr\u003e ▸ EER: 2.92\u003cbr\u003e\u003cbr\u003e ▸ Seasonal room heating Energy efficiency class⁶: LWT at 35 °C: A++\u003cbr\u003e ▸ SCOP6: LWT at 35 °C: 4.29\u003cbr\u003e ▸ SEER6:\u003cbr\u003e ▸ LWT at 7 °C: 4.85\u003cbr\u003e ▸ LWT at 18 °C: 7.50\u003cbr\u003e\u003cbr\u003e ▸ Sound level⁷: 68 dB(A)\u003cbr\u003e ▸ Outdoor fan: air flow 6150 m3\/h\u003cbr\u003e ▸ Net dimensions (WxHxD): 1404×1414×405 mm\u003cbr\u003e ▸ Dimensions with packaging (WxHxD): 1475×1580×440\u003cbr\u003e ▸ Net\/gross weight: 158\/178 kg\u003cbr\u003e ▸ Water pipe connections: 1 - 1\/4” AG BSP\u003cbr\u003e ▸ Safety valve response pressure: 0.3 MPa\u003cbr\u003e ▸ Total water volume: 5.5 L\u003cbr\u003e\u003cbr\u003e ▸ Operating temperature range:\u003cbr\u003e ▸ Cooling: -5 to 46°C\u003cbr\u003e ▸ Heating: -25 to 35°C\u003cbr\u003e ▸ DHW: -25 to 43°C\u003cbr\u003e\u003cbr\u003e ▸ LWT area:\u003cbr\u003e ▸ Cooling: 5 to 25\u003cbr\u003e ▸ Heating: 25 to 60\u003cbr\u003e ▸ DHW: 40 to 60\u003cbr\u003e\u003cbr\u003e ▸ Refrigerant\u003cbr\u003e ▸ Type: R32\u003cbr\u003e ▸ Loaded volume: 2.0 kg\u003cbr\u003e\u003cbr\u003e ▸ Throttle valve type: Electronic expansion valve\u003cbr\u003e ▸ Additional electric heating: Optional ✓: 3.0 kW\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e 1. Relevant EU standards and legislation: EN14511: 2016; EN14825: 2016; \u003cbr\u003eEN50564: 2011; EN12102:2017; (EU) N° 811\/2013; (EU) N° 813\/2013;\u003cbr\u003e OJ 2014\/C 207\/02; OJ 2017\/C 229\/01.\u003cbr\u003e 2. Outdoor temperature 7°C DB, 85% RH; EWT 30°C, LWT 35°C.\u003cbr\u003e 3. Outdoor temperature 7°C DB, 85% RH; EWT 47°C, LWT 55°C.\u003cbr\u003e 4. Outside temperature 35°C DB; EWT 23°C, LWT 18°C.\u003cbr\u003e 5. Outside temperature 35°C DB; EWT 12°C, LWT 7°C.\u003cbr\u003e 6. Energy efficiency class of seasonal space heating, tested under\u003cbr\u003e average climatic conditions\u003cbr\u003e 7. Sound power level tested under average climatic conditions:\u003cbr\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 30°C, LWT 35°C;\u003cbr\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 47°C, LWT 55°C;\u003cbr\u003e - cooling: outside temperature 35°C DB, 24°C WB; EWT 12°C, LWT 7°C\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan\u003eTechnical data heat pump 14 kW\u003cbr\u003e ▸ Power supply: V\/Ph\/Hz 380-415\/3\/50\u003cbr\u003e\u003cbr\u003e heating²\u003cbr\u003e ▸ Capacity kW: 14.10\u003cbr\u003e ▸ Nominal power input kW: 3.05\u003cbr\u003e ▸ COP: 4.63\u003cbr\u003e\u003cbr\u003e heating³\u003cbr\u003e ▸ Capacity kW: 14.20\u003cbr\u003e ▸ Nominal power input kW: 5.10\u003cbr\u003e ▸ COP: 2.79\u003cbr\u003e\u003cbr\u003e cooling⁴\u003cbr\u003e ▸ Capacity kW: 14.00\u003cbr\u003e ▸ Nominal power input kW: 3.11\u003c\/span\u003e \u003cbr\u003e▸ EER: 4.50\u003cbr\u003e\u003cbr\u003e cooling⁵\u003cbr\u003e ▸ Capacity kW: 12.90\u003cbr\u003e ▸ Nominal power input kW: 4.62\u003cbr\u003e ▸ EER: 2.80\u003cbr\u003e\u003cbr\u003e Seasonal space heating\u003cbr\u003e ▸ Energy efficiency class⁶\u003cbr\u003e ▸ LWT at 35 °C A++\u003cbr\u003e ▸ LWT at 55 °C A++\u003cbr\u003e ▸ SCOP6 LWT at 35 °C 4.27\u003cbr\u003e ▸ LWT at 55 °C 3.26\u003cbr\u003e ▸ SEER6 LWT at 7 °C 4.73\u003cbr\u003e ▸ LWT at 18 °C 7.16\u003cbr\u003e ▸ Sound level⁷ dB(A) 71\u003cbr\u003e\u003cbr\u003e ▸ Outdoor fan air flow: m3 \/h 6150\u003cbr\u003e ▸ Net dimensions (WxHxD) mm: 1404×1414×405\u003cbr\u003e ▸ Dimensions with packaging (WxHxD): mm 1475×1580×440\u003cbr\u003e ▸ Net\/gross weight kg: 172\/193\u003cbr\u003e ▸ Water pipe connections: mm 1-1\/4” Male BSP\u003cbr\u003e ▸ Safety valve response pressure: MPa 0.3\u003cbr\u003e ▸ Total water quantity: L 5.5\u003cbr\u003e\u003cbr\u003e operating temperature range\u003cbr\u003e ▸ Cooling: °C -5 to 46\u003cbr\u003e ▸ Heating: °C -25 to 35\u003cbr\u003e ▸ DHW: °C -25 to 43\u003cbr\u003e\u003cbr\u003e LWT area\u003cbr\u003e ▸ Cooling: °C 5 to 25\u003cbr\u003e ▸ Heating: °C 25 to 60\u003cbr\u003e ▸ DHW °C: 40 to 60\u003cbr\u003e\u003cbr\u003e ▸ Refrigerant type: R32\u003cbr\u003e ▸ Loaded volume kg: 2.8\u003cbr\u003e ▸ Throttle valve type Electronic expansion valve\u003cbr\u003e\u003cbr\u003e 1. Relevant EU standards and legislation: EN14511: 2016; EN14825: 2016; \u003cbr\u003eEN50564: 2011; EN12102:2017; (EU) N° 811\/2013; (EU) N° 813\/2013;\u003cbr\u003e OJ 2014\/C 207\/02; OJ 2017\/C 229\/01.\u003cbr\u003e 2. Outdoor temperature 7°C DB, 85% RH; EWT 30°C, LWT 35°C.\u003cbr\u003e 3. Outdoor temperature 7°C DB, 85% RH; EWT 47°C, LWT 55°C.\u003cbr\u003e 4. Outside temperature 35°C DB; EWT 23°C, LWT 18°C.\u003cbr\u003e 5. Outside temperature 35°C DB; EWT 12°C, LWT 7°C.\u003cbr\u003e 6. Energy efficiency class of seasonal space heating, tested under\u003cbr\u003e average climatic conditions\u003cbr\u003e 7. Sound power level tested under average climatic conditions:\u003cbr\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 30°C, LWT 35°C;\u003cbr\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 47°C, LWT 55°C;\u003cbr\u003e - cooling: outside temperature 35°C DB, 24°C WB; EWT 12°C, LWT 7°C.\u003cbr\u003e Electric auxiliary heating Optional kW 3.0\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan\u003eTechnical data heat pump 16 kW\u003cbr\u003e ▸ Power supply V\/Ph\/Hz 380-415\/3\/50\u003cbr\u003e\u003cbr\u003e heating²\u003cbr\u003e ▸ Capacity kW: 16.30\u003cbr\u003e ▸ Rated input power kW: 3.63\u003cbr\u003e ▸ COP: 4.49\u003cbr\u003e\u003cbr\u003e heating³\u003cbr\u003e ▸ Capacity kW: 16.10\u003cbr\u003e ▸ Nominal power input kW: 5.83\u003cbr\u003e ▸ COP: 2.76\u003cbr\u003e\u003cbr\u003e cooling⁴\u003c\/span\u003e \u003cbr\u003e▸ Capacity kW: 15.50\u003cbr\u003e ▸ Rated input power kW: 3.63\u003cbr\u003e ▸ EER: 4.27\u003cbr\u003e\u003cbr\u003e cooling⁵\u003cbr\u003e ▸ Capacity kW: 13.80\u003cbr\u003e ▸ Nominal power input kW: 5.19\u003cbr\u003e ▸ EER: 2.66\u003cbr\u003e\u003cbr\u003e Seasonal space heating\u003cbr\u003e ▸ Energy efficiency class⁶\u003cbr\u003e ▸ LWT at 35 °C A++\u003cbr\u003e ▸ LWT at 55 °C A++\u003cbr\u003e ▸ SCOP6 LWT at 35 °C 4.30\u003cbr\u003e ▸ LWT at 55 °C 3.27\u003cbr\u003e ▸ SEER6 LWT at 7 °C 4.54\u003cbr\u003e ▸ LWT at 18 °C 6.78\u003cbr\u003e ▸ Sound level⁷ dB(A): 71\u003cbr\u003e ▸ Outdoor fan air flow: m3 \/h 6150\u003cbr\u003e\u003cbr\u003e ▸ Net dimensions (WxHxD): mm 1404×1414×405\u003cbr\u003e ▸ Dimensions with packaging (WxHxD): mm 1475×1580×440\u003cbr\u003e ▸ Net\/gross weight kg: 172\/193\u003cbr\u003e ▸ Water pipe connections: mm 1-1\/4” Male BSP\u003cbr\u003e ▸ Safety valve response pressure: MPa 0.3\u003cbr\u003e ▸ Total water quantity: L 5.5\u003cbr\u003e\u003cbr\u003e operating temperature range\u003cbr\u003e ▸ Cooling °C -5 to 46\u003cbr\u003e ▸ Heating °C -25 to 35\u003cbr\u003e ▸ DHW °C -25 to 43\u003cbr\u003e ▸ LWT area\u003cbr\u003e ▸ Cooling °C 5 to 25\u003cbr\u003e ▸ Heating °C 25 to 60\u003cbr\u003e ▸ DHW °C 40 to 60\u003cbr\u003e ▸ Refrigerant type R32\u003cbr\u003e ▸ Loaded volume kg 2.8\u003cbr\u003e ▸ Throttle valve type Electronic expansion valve\u003cbr\u003e ▸ Electric auxiliary heating Optional kW 3.0\u003cbr\u003e \u003cbr\u003e1. Relevant EU standards and legislation: EN14511: 2016; EN14825: 2016;\u003cbr\u003e EN50564: 2011; EN12102:2017; (EU) N° 811\/2013; (EU) N° 813\/2013;\u003cbr\u003e OJ 2014\/C 207\/02; OJ 2017\/C 229\/01.\u003cbr\u003e 2. Outdoor temperature 7°C DB, 85% RH; EWT 30°C, LWT 35°C.\u003cbr\u003e 3. Outdoor temperature 7°C DB, 85% RH; EWT 47°C, LWT 55°C.\u003cbr\u003e 4. Outside temperature 35°C DB; EWT 23°C, LWT 18°C.\u003cbr\u003e 5. Outside temperature 35°C DB; EWT 12°C, LWT 7°C.\u003cbr\u003e 6. Energy efficiency class of seasonal space heating, tested under\u003cbr\u003e average climatic conditions\u003cbr\u003e 7. Sound power level tested under average climatic conditions:\u003cbr\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 30°C, LWT 35°C;\u003cbr\u003e - heating: outside temperature 7°C DB, 6°C WB; EWT 47°C, LWT 55°C;\u003cbr\u003e - cooling: outside temperature 35°C DB, 24°C WB; EWT 12°C, LWT 7°C.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e Manufacturer information: \u003ca href=\"http:\/\/www.mitsuiheatpumps.com\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e \u003cspan style=\"font-weight: bold; background: white;\"\u003eENVIRON Energie- und Umwelttechnik GmbH \u0026amp; Co. KG\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e \u003cspan style=\"background: white;\"\u003eRobert-Bosch-Straße 9\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e\u003cspan style=\"background: white;\"\u003e78048 Villingen-Schwenningen\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e \u003cspan style=\"background: white;\"\u003ePhone: +49 7705 977 5803\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e E- \u003cspan style=\"background: white;\"\u003eMail:\u003c\/span\u003e \u003ca href=\"mailto:info@environgroup.de\"\u003e\u003cspan style=\"background: white;\"\u003einfo@environgroup.de\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e Website: \u003ca href=\"https:\/\/environ-solutions.de\/\"\u003ehttps:\/\/environ-solutions.de\/\u003c\/a\u003e \u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e \u003cspan style=\"font-weight: bold;\"\u003eHolistic Energy Concepts GmbH \u0026amp;amp; Co. KG\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e Überaucher Straße 9\/1\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e 78052 Villingen-Schwenningen\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e Germany\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e Phone: +49 7705 9769690\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e Email: info@ganzheitliche-energiekonzepte.de\u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e Website: \u003ca href=\"http:\/\/www.mitsuiheatpumps.com\"\u003ewww.mitsuiheatpumps.com\u003c\/a\u003e \u003c\/p\u003e\n\n\u003cp style=\"margin: 0in; font-family: Arial; font-size: 10.0pt;\"\u003e\u003c\/p\u003e","brand":"Environ","offers":[{"title":"5kW","offer_id":43719168098568,"sku":"0746052539227","price":6554.99,"currency_code":"EUR","in_stock":true},{"title":"7kW","offer_id":43719168131336,"sku":"0746052539210","price":6852.99,"currency_code":"EUR","in_stock":true},{"title":"9kW","offer_id":43719168164104,"sku":"0746052539203","price":6192.19,"currency_code":"EUR","in_stock":true},{"title":"12kW","offer_id":43719168196872,"sku":"0746052539197","price":6816.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0544\/7270\/4189\/files\/WaermepumpenSetHygienespeicher-new_1.webp?v=1754560166","url":"https:\/\/ganz24.com\/en\/products\/environ-warmepumpe-mit-550-liter-hygienespeicher-fur-brauchwasser-und-heizung","provider":"ganz24","version":"1.0","type":"link"}