A+++ Environ EcoHeat Monoblock heat pump – Highest efficiency for your home
The Environ EcoHeat monoblock heat pump combines the latest technology, maximum efficiency and environmental friendliness. Developed in Germany by a family-run company with tradition and a focus on quality, it ensures sustainable energy use and the lowest heating costs. Perfect for new buildings and renovations!
Why choose Environ EcoHeat?
-
Highest energy efficiency: With A+++ and a SCOP of up to 4.58, you can drastically reduce your energy costs.
-
Versatile applications: Power levels from 6 to 24 kW – suitable for every building size.
-
Durable and maintenance-free: Designed for minimal maintenance and maximum service life.
-
Easy installation: Monoblock design for quick, hassle-free connections.
-
Environmentally friendly: Operates with R32 refrigerant , which reduces the CO₂ footprint.
-
Reliable in all weather conditions: Works even at temperatures down to -25 °C .
Additional features
-
Hydraulic system: Built-in circulation pump for optimized heating and cooling performance.
-
Noise protection: silencer feet and optimized fans for particularly quiet operation.
-
Energy consumption: Efficient operation with minimal power consumption (e.g. ENHP-6 at 1.31 kW input power).
-
Frost protection: Safe operation even at very low temperatures.
-
Water flow (m³/h): Up to 4.12 m³/h depending on model for optimal performance.
scope of delivery
- 1x Environ EcoHeat monoblock heat pump (depending on model)
- 1x user manual
- 1x Wired Controller
- 6x temperature sensors
- 2x silencer feet
areas of application
- Heating and cooling for residential and commercial spaces.
- Drinking water heating – ideal in combination with underfloor heating.
- Solar integration – using renewable energy to increase efficiency.
Sustainability & Innovation
Environ stands for German quality and environmentally friendly technology. With the EcoHeat monoblock heat pump, you heat sustainably and save costs in the long term. Your contribution to the energy transition starts here - efficient, honest, sustainable.
👉 Assembly and operating instructions
feature |
Unit |
ENHP-6-R32 |
ENHP-10-R32 |
ENHP-14-R32 |
ENHP-18-R32 |
ENHP-24-R32 |
power supply |
/ |
220-240~/50Hz |
220-240~/50Hz |
380-415/3N~/50Hz |
380-415/3N~/50Hz |
380-415/3N~/50Hz |
heating output range |
kW |
2.50-8.30 |
4.20-12.20 |
5.30-16.50 |
6.20-19.80 |
6:00-26.10 |
Test standard: EN14511 - Ambient temperature: 7°C/6°C (DB/WB), Water inlet/outlet: 30°C/35°C |
nominal heating output |
kW |
6.46 |
10:58 |
14.75 |
18.77 |
23.98 |
rated input power |
kW |
1.31 |
2.29 |
3.21 |
4.16 |
5.52 |
coefficient of performance |
/ |
4.93 |
4.62 |
4.6 |
4.51 |
4.34 |
Test standard: EN14511 Ambient temperature: 7°C/6°C (DB/WB), Water inlet/outlet: 47°C/55°C |
nominal heating output |
kW |
5.53 |
8.54 |
12.95 |
15.88 |
20:44 |
rated input power |
kW |
1.82 |
2.84 |
4.51 |
5.36 |
7:15 |
coefficient of performance |
/ |
3.04 |
3.00 |
2.87 |
2.96 |
2.86 |
Test standard: EN14511 Ambient temperature: 35°C/24°C (DB/WB), Water inlet/outlet: 12°C/7°C |
nominal heating output |
kW |
5.53 |
8.54 |
12.95 |
15.88 |
20:44 |
rated input power |
kW |
1.82 |
2.84 |
4.51 |
5.36 |
7:15 |
coefficient of performance |
/ |
3.04 |
3.00 |
2.87 |
2.96 |
2.86 |
Test Standard: EN14511 Ambient Temperature: 35°C/24°C (DB/WB), Water Inlet/Outlet: 23°C/18°C |
nominal heating output |
kW |
6.55 |
10.27 |
13.77 |
16:58 |
21.34 |
rated input power |
kW |
1.47 |
2.43 |
3.52 |
4.47 |
5.13 |
coefficient of performance |
/ |
4.46 |
4.23 |
3.92 |
4.09 |
4.16 |
Test standard: EN14825-2022/EN12102-2022 Low temperature application (35°C) |
SCOP |
/ |
4.58 |
4.47 |
4.50 |
4.53 |
4.51 |
energy efficiency class |
/ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
sound pressure level (1 m) |
dB(A) |
49 |
52 |
54 |
55 |
56 |
sound power level (1 m) |
dB(A) |
63 |
66 |
68 |
70 |
72 |
Test standard: EN14825-2022/EN12102-2022 Medium temperature application (55°C) |
SCOP |
/ |
3.23 |
3.24 |
3.25 |
3.28 |
3.32 |
energy efficiency class |
/ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
sound pressure level (1 m) |
dB(A) |
48 |
50 |
54 |
55 |
58 |
sound power level (1 m) |
dB(A) |
63 |
64 |
69 |
71 |
73 |
operating temperature |
°C |
-25~45 |
-25~45 |
-25~45 |
-25~45 |
-25~45 |
Test standard: EN14825-2022/EN12102-2022 Medium temperature application (55°C) |
SCOP |
/ |
3.23 |
3.24 |
3.25 |
3.28 |
3.32 |
energy efficiency class |
/ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
sound pressure level (1 m) |
dB(A) |
48 |
50 |
54 |
55 |
58 |
sound power level (1 m) |
dB(A) |
63 |
64 |
69 |
71 |
73 |
operating temperature |
°C |
-25~45 |
-25~45 |
-25~45 |
-25~45 |
-25~45 |
Max. outlet water temperature |
°C |
60 |
60 |
60 |
60 |
60 |
Max. input power |
kW |
2.71 |
3.83 |
6.20 |
7.50 |
10 |
Max. current consumption |
A |
12 |
17 |
10.5 |
13 |
17 |
refrigerant weight |
kg |
1.25 |
1.8 |
2.8 |
3.5 |
3.5 |
refrigerant type |
/ |
R32 |
R32 |
R32 |
R32 |
R32 |
operating pressure (low pressure side) |
MPa |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
operating pressure (high-pressure side) |
MPa |
4.4 |
4.4 |
4.4 |
4.4 |
4.4 |
water pipe connections |
MPa |
4.4 |
4.4 |
4.4 |
4.4 |
4.4 |
expansion tank |
inch |
G1" |
G1" |
G1 1/4” |
G1 1/2” |
G1 1/2” |
water pressure drop |
L |
/ |
/ |
/ |
6 |
6 |
Water Pressure Drop |
kPa |
25 |
27 |
30 |
32 |
35 |
Test standard: EN14825-2022/EN12102-2022 Medium temperature application (55°C) |
Water Pressure Drop |
kPa |
0.1 / 0.3 |
0.1 / 0.3 |
0.1 / 0.3 |
0.1 / 0.3 |
0.1 / 0.3 |
water flow nominal value |
m3/h |
1.1 |
1.75 |
2.52 |
3.2 |
4.12 |
net weight |
Kg |
102 |
107 |
124 |
151 |
160 |
Note: Parameters are subject to change without prior notice. Please refer to the device's rating plate. |
Manufacturer information:
ENVIRON Energie- und Umwelttechnik GmbH & Co. KG
Robert-Bosch-Straße 9
78048 Villingen-Schwenningen
Phone: +49 7705 977 5803
E- Mail: info@environgroup.de
Website: https://environ-solutions.de/